Portable Generator Placement and Carbon Monoxide
An Open Door Does Not Make a Generator Safe Indoors

A power cut can turn a convenient generator location into a serious exposure. A fuel-powered portable generator produces carbon monoxide: a poisonous gas that you cannot see or smell. Running it inside a workshop, garage or site cabin with the door open does not make that location safe. Even an outdoor generator can send exhaust through a nearby opening. Choose its position before power is needed, not after people begin feeling unwell.
Controls to confirm
- Keep the engine outdoors: never operate a fuel-powered portable generator inside a building or an enclosed or partly enclosed space. An open door, window or fan does not make an indoor position acceptable. If the proposed location cannot provide safe outdoor operation, arrange another power source before starting work.
- Separate exhaust from occupied spaces: keep the generator more than 20 feet (about 6.1 metres) from doors, windows and vents, following CDC guidance. Check nearby cabins and adjoining buildings as well as your own work area. Keep the manufacturer's required ventilation clearances; OSHA advises 3 to 4 feet of clear space around and above the unit. Follow any stricter manufacturer or local requirements.
- Respond immediately to suspected exposure: headache, dizziness, nausea, unusual tiredness or confusion near a running generator may indicate carbon monoxide poisoning. Move to fresh air immediately, alert others and call emergency medical help. Do not enter a suspect atmosphere to retrieve equipment or rescue someone without trained, properly equipped responders. Re-entry must wait until competent responders establish that the area is safe.
Today’s action
Before today's portable generator starts, walk its proposed location with the supervisor. Measure separation from openings, confirm outdoor airflow and agree the emergency response. Move an unsuitable setup before connecting the load.
Source guidance
Authoritative guidance checked 19 October 2026. Apply the legal requirements and approved procedures for your location.
- US OSHA — Portable generators: outdoor placement, ventilation clearance, poisoning symptoms and safe re-entry
- CDC — Carbon Monoxide Poisoning Basics: invisible, odourless hazard; never run generators indoors even with doors open; more than 20 feet from openings
- CDC — Use a Generator Safely: outdoor separation from doors, windows and vents
Future HSSE email updates
Register interest in HSSE email updates.
Record your interest in future Worksite Safety Hub messages, selected HSSE news and new-resource alerts. Email delivery is not connected yet.
Your experience matters
Share your thoughts on this page
Have a question, a useful experience or a suggestion? Add your input below.
Comments are public. Keep them respectful and relevant. Do not share contact details, confidential information or emergency reports.
Comments on this page
Loading comments…